Sterilizator Medical Sterilmed
Model SMB-SSD-450 Single door
Dispozitiv Medical în conformitate cu: 93/42/EEC as amended by directive 2007/47/EC
Clasificare: Class II B, acc. To EC MDD 93/42/EEC 2007/47/EC (Annex II)
Directiva: 2006/95/EC – EN 60601-2-040
EMC Directive: : 2004/108/EC EN 60601-1-2
Pressure Equipment Directive: 2014/68/EU : EN 13445-1, -2, -3, -4, -5 (Pressure Vessels)
Sterilization – Steam sterilizers – Large sterilizers: EN285:2016
Standard calitate: EN – ISO 9001:2015
Medical Devices – Quality management systems: ISO 13485:2016
Environmental Management Systems: ISO 14001:2015
Type” tests of STERİLMED steam sterilizers are performed and certified according to the directives of EN 285 and TS EN 17665-1-2 by The German accreditation company HYGCEN GmbH.
Generalitati:
☑ Controller sterilizator: PLC (Programmable Logic Controller)
☑ Mod operare : full automatic
☑ Display: Color TFT, LCD Touch Screen
☑ Tastatură: Touchscreen
☑ Printer inclus : 40 Character/line, Integrated Thermal Printer
☑ Alarme : Visual & Audio & Printed Alarms
☑ Memorie : 1000 cycles
Specificitatii tehnice
☑ volum cameră sterilizare : 450 Litri
☑ temperatură sterilizare: 105°C – 141°C
☑ senzor temperatură :PT 100 Sensor
☑ senzori presiune : 3 unitati localizate :1 buc în mantaua sterilizatorului, 1 buc în camera sterilizare , 1 buc în compresor
☑ vacuum : 60 mbar
☑ pre-vacuum : DA
☑ material constructiv: otel inoxidabil AISI 304-316 L/Ti S.S. vopsit în camp electrostatic
☑ cameră sterilizare : Rectangulară, grosime 6 mm, material AISI 316 L/Ti Stainless Steel
☑ material constructiv exterior: grosime 3 mm, AISI 316 L/Ti Stainless Steel, Full Cover
☑ usa : grosime 10 mm, AISI 304-316 L/Ti Stainless Steel
☑ tubulatură și panouri : AISI 304-316 L/Ti Stainless Steel
☑ conditii electrice instalare : 3 Phase / 380 VAC ±10
☑ calitate apă : apă deionizată sau apă distilată
☑ putere consum energie : 10 kW/ Per Cycle
☑ consum apă :80 Lt/ Per Cycle
☑ Generator de abur : capacitate 50 L-89 L ,Built in Steam Generator or Central Steam System
☑ Protectie nivel apă : CRES* / AISI 304 steel box
☑ dimensiuni cameră sterilizare : 670 x 670 x 1000 mm
☑ dimensiuni generale : 1140 x 1900 x 1400 mm
Programe Standard :
☑ instrumentar medical&chirurgical :(134°C) timp de 60 min
☑ lenjerii & uniforme medicale: (134°C) timp de 60 min
☑ materiale din cauciuc : (121°C) timp de 80 min
☑ lichide & sticlarie de laborator: (121°C) timp de 60 min
☑ implanturi silicon & produse din silicon: (134°C) timp de 80 min
☑ PRION: (134°C) timp de 90 min
☑ Bowie & Dick Test: (134°C) timp de 45 min
Dispunem de Sterilizitatoare STERILMED de volume : 100, 160, 200, 250, 377, 580, 850 si 985 Litri.